AJP - Regu Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Regul Integr Comp Physiol 265: R195-R202, 1993;
0363-6119/93 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Geerdes, B. P.
Right arrow Articles by Brunner, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Geerdes, B. P.
Right arrow Articles by Brunner, M. J.

AJP - Regulatory, Integrative and Comparative Physiology, Vol 265, Issue 1 195-R202, Copyright © 1993 by American Physiological Society


ARTICLES

Carotid baroreflex control during hemorrhage in conscious and anesthetized dogs

B. P. Geerdes, K. L. Frederick and M. J. Brunner
Department of Surgery, University of Maryland, Baltimore 21201.

The hypothesis was tested that carotid baroreflex gain is increased after 20% hemorrhage. The baroreceptor reflex responses to changes in carotid sinus pressure (CSP) were measured in control, 20% hemorrhage, and reinfusion conditions in three experimental groups: conscious intact (n = 7), anesthetized intact (n = 8), and anesthetized vagotomized (n = 8) dogs. Mean arterial pressure (MAP), heart rate (HR), cardiac output (CO), stroke volume (SV), and calculated total peripheral resistance (TPR) responses to changes in CSP were measured. At any given CSP, MAP, CO, and SV all decreased significantly with the 20% hemorrhage, as reflected by a downward shift in the reflex characteristic curve with no change in overall reflex range or gain. In contrast, TPR and HR responses to CSP were not significantly altered by 20% hemorrhage; reflex curves and gains were comparable to control conditions. In the conscious intact dogs, the maximal reflex gain, Gmax, for the MAP response was -1.365 +/- 0.25, -1.298 +/- 0.33, and -1.324 +/- 0.25 in control, 20% hemorrhage, and reinfusion conditions, respectively, and was not significantly altered by hemorrhage. In the same group, the Gmax for the HR response was -1.792 +/- 0.65, -1.709 +/- 0.33, and -1.986 +/- 0.67 in control, 20% hemorrhage, and reinfusion conditions, respectively; baroreflex gain on HR was not increased with hemorrhage. Plasma arginine vasopressin (AVP), an increase in which has been proposed to augment baroreflex gain, increased from a control level of 0.98 +/- 0.27 to 9.66 +/- 2.67 pg/ml during 20% hemorrhage in the conscious intact dogs; despite the increase in plasma AVP during hemorrhage, augmentation of baroreflex gain was not observed.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
H. Gu, M. Lin, J. Liu, D. Gozal, K. E. Scrogin, R. Wurster, M. W. Chapleau, X. Ma, and Z. Cheng
Selective impairment of central mediation of baroreflex in anesthetized young adult Fischer 344 rats after chronic intermittent hypoxia
Am J Physiol Heart Circ Physiol, November 1, 2007; 293(5): H2809 - H2818.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
B. R. Dworkin, X. Tang, A. J. Snyder, and S. Dworkin
Carotid and aortic baroreflexes of the rat: II. Open-loop frequency response and the blood pressure spectrum
Am J Physiol Regulatory Integrative Comp Physiol, November 1, 2000; 279(5): R1922 - R1933.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online