AJP - Regu AJP: Endocrinology and Metabolism
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Regul Integr Comp Physiol 272: R1595-R1598, 1997;
0363-6119/97 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Drake, R. E.
Right arrow Articles by Gabel, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Drake, R. E.
Right arrow Articles by Gabel, J. C.

AJP - Regulatory, Integrative and Comparative Physiology, Vol 272, Issue 5 1595-R1598, Copyright © 1997 by American Physiological Society


ARTICLES

Lymph flow in sheep with rapid cardiac ventricular pacing

R. E. Drake, S. Dhother, R. A. Teague and J. C. Gabel
Department of Anesthesiology, University of Texas Medical School, Houston 77030, USA.

Increases in systemic venous pressure (Pv) associated with heart failure cause an increase in microvascular fluid filtration into the tissue spaces. By removing this excess filtrate from the tissues, lymphatic vessels help to prevent edema. However, the lymphatics drain into systemic veins and an increase in Pv may interfere with lymphatic flow. To test this, we cannulated caudal mediastinal node efferent lymphatics in sheep. We used rapid cardiac ventricular pacing (240-275 beats/min) to cause heart failure for 4-7 days. Each day we determined the lymph flow rate two ways. First, we adjusted the lymph cannula height so that the pressure at the outflow end of the lymphatic was zero. After we determined the lymph flow with zero outflow pressure, we raised the cannula so that outflow pressure was equal to the actual venous pressure. We quantitated the effect of venous pressure on lymph flow rate by comparing the flow rate with outflow pressure = Pv to the flow rate with zero out low pressure. At baseline, Pv = 5.0 +/- 2.5 (SD) cmH2O and we found no difference in the two lymph flow rates. Pacing caused Pv and both lymph flow rates to increase significantly. However for Pv < 15 cmH2O, we found little difference in the two lymph flow rates. Thus increases in Pv to 15 cmH2O at the outflow to the lymphatics had little effect on lymph flow. By comparison, Pv > 15 cmH2O slowed lymph flow by 55 +/- 29% relative to the lymph flow rate with zero outflow pressure. Thus Pv values > 15 cmH2O interfere with lymph flow from the sheep caudal mediastinal lymph node.


This article has been cited by other articles:


Home page
JCOHome page
A. Partridge, S. Nasser, and S. Dzik
Nonmalignant Diagnoses in Patients
J. Clin. Oncol., July 1, 2000; 18(13): 2635 - 2636.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online