|
|
||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
WATER AND ELECTROLYTE HOMEOSTASIS
1Department of Surgery, Veterans Affairs Medical Center, Durham; 2Division of Urology, Department of Surgery, Duke University Medical Center, Durham; 3Department of Pathology, Duke University Medical Center, Durham; 4Department of Urology, Affiliated 6th People's Hospital, Shanghai Jiaotong University, Shanghai, People's Republic of China; 5Urogenics Pharmaceuticals, Inc., Durham; 6Division of Gynecologic Specialties, Department of Obstetrics and Gynecology, Duke University Medical Center, Durham; and 7Institute of Statistics and Decision Sciences, Duke University, Durham, North Carolina
Submitted 28 February 2006 ; accepted in final form 20 December 2006
| ABSTRACT |
|---|
|
|
|---|
bladder; micturition; neurogenic voiding; detrusor; urethra
This important supraspinal control system is lost when spinal cord transsection interrupts axons of the brain stem 5-HT-producing neurons. However, 5-HT1A receptors remain within the spinal cord following destruction of descending 5-HT-containing pathways in the rat (20, 29) and spinal cord transsection in the cat (12). Thus, 5-HT receptor agonists remain potential therapeutic agents in the setting of spinal cord injury. This therapeutic potential is supported by our recent finding that the 5-HT1A/7 receptor agonist [(R)-(+)-8-hydroxy-2-di-n-propylamino]tetralin (8-OH-DPAT) increases bladder capacity in chronic spinal cord-injured cats (15). In contrast, previous studies in rats with chronic spinal cord injury showed that intrathecal 8-OH-DPAT promoted bladder contractions under isovolumetric conditions (21). However, those conditions do not allow for a full assessment of the effects of 5-HT1A receptor ligands on micturition, a process involving the entire lower urinary tract (e.g., bladder capacity, micturition volume, residual volume, and EUS effects).
In spinally intact cats, EUS activity is minimal during voiding and under nociceptive but not innocuous conditions 8-OH-DPAT enhances EUS activity between voids without interfering with the EUS relaxation during voids (35). In spinally intact rats, on the other hand, alternating EUS activation and relaxation occurs at about 6 Hz during voiding (19). Voiding efficiency in spinally intact rats is reduced when this phasic EUS activity during voiding is prevented (37). In spinal cord-injured rats, tonic rather than phasic EUS-electromyography (EUS-EMG) activity occurs during bladder contractions (19), commonly producing overflow incontinence. The effect of 8-OH-DPAT on phasic EUS-EMG activity in spinally intact and spinal cord-injured rats has not been previously described.
In this study, we examine the effect of 8-OH-DPAT on micturition during open cystometry in chronic spinal cord-injured rats, paying particular attention to the activity of the EUS.
| MATERIALS AND METHODS |
|---|
|
|
|---|
Cystometric methods. General cystometric methods were much as we have previously described (14). Rats were anesthetized with urethane (1.3 g/kg sc; Sigma, St. Louis, MO); at this dose level, anesthesia was very long lasting and did not require supplementation. A polyethylene (PE)-50 catheter was placed in the left jugular vein for intravenous drug administration. The urinary bladder was exposed via a midline abdominal incision, a PE-90 catheter with a flared end was inserted through the bladder dome, and a suture was tightened around it. The other end of the bladder catheter was connected to a syringe pump (model 975; Harvard Apparatus, South Natick, MA) for continuous infusion of saline and to a pressure transducer (model P23XL-1; Gould Ohmeda, Valley View, OH) for intravesical pressure monitoring. Physiological saline was infused at room temperature into the bladder to elicit repeated voiding responses. The infusion rate was 0.110.15 ml/min for spinally intact rats and 0.301.10 ml/min for spinal cord-injured rats (similar to Ref. 19); the higher rate of infusion is necessary in spinal cord-injured rats with their enlarged bladders to ensure the occurrence of a voiding contraction within 10 min of drug administration. The voided fluid was collected in a syringe connected to a force transducer (model A-934; Kulite, Leonia, NJ) which was calibrated to determine the micturition volume. Intravesical pressure and micturition volume were sampled at 50 Hz. The cystometric variables analyzed were micturition volume (voided volume), residual volume (volume remaining in the bladder after voiding), bladder capacity (micturition volume plus residual volume), and peak intravesical pressure.
EUS-EMG. To record the EUS-EMG, 0.005-in. diameter Medwire AG5T polytetrafluorethylene-coated silver wire electrodes (Sigmund Cohn, Mount Vernon, NY) were inserted percutaneously into the vicinity of the EUS. The electrodes were connected through a model HIP5 high-impedance probe (Grass, Quincy, MA) to a Grass P5 preamplifier. EUS-EMG data were sampled at 5,000 Hz, 510 times the frequency of the major peaks as recommended to prevent aliasing (6). During voiding, the EUS-EMG of urethane-anesthetized spinally intact rats is characterized by a series of alternating bursts and pauses. In urethane-anesthetized spinal cord-injured rats, activity was tonic during voiding contractions (bladder-sphincter dyssynergia), which consequently result only in overflow incontinence; however, pauses interrupting the otherwise tonic activity were elicited by 8-OH-DPAT treatment. The characteristics of the alternating bursts and pauses were very variable in the drug-treated spinal cord-injured rats, which made unbiased counting of the pauses difficult. However, empirical study using a wide variety of signal analysis techniques failed to improve upon unassisted human counting. Accordingly, counts of pauses in the EUS-EMG activity records were made by an observer blinded to treatment.
Experimental protocols. Three different experimental protocols were employed in the course of this study; data from different protocols were not combined. Protocol 1 (3 spinally intact and 2 spinal cord-injured rats) included both free-running cystometry (continuous infusion with reflex voiding) and filling cystometry (filling of the initially empty bladder until the beginning of voiding). After a few free-running micturition cycles, vehicle or drug was administered, and the ensuing response was observed for a few more cycles. The bladder was then emptied and three reproducible filling cystometrograms were obtained at each vehicle or drug dosage before returning to free-running conditions. In protocol 2 (5 spinally intact and 6 spinal cord-injured rats), free-running cystometry was omitted; after at least three reproducible filling cystometrograms were obtained, vehicle or 8-OH-DPAT was administered (0.0031 mg/kg iv) and then another filling cystometrogram was performed from which measurements were taken. Successive doses were administered cumulatively at short intervals (22 min maximum). The 5-HT1A receptor antagonist N-tert-butyl-3-[4-(2-methoxyphenyl)-piperazin-1-yl]-2-phenylpropanamide(WAY-100635) was administered at 0.3 mg/kg iv after each 8-OH-DPAT dose-response curve in both protocols 1 and 2. Protocol 3 (4 spinally intact rats) was the same as protocol 2 except that a dose-response study for the 5-HT1A receptor antagonist WAY-100635 (0.0030.3 mg/kg iv) rather than 8-OH-DPAT was performed.
Drugs. 8-OH-DPAT and WAY-100635 (both from Sigma) were dissolved in distilled water. Affinities (pKi values) of 8-OH-DPAT at 5-HT1A and 5-HT7 receptors are 8.7 and 7.4, respectively (16), while the pKi of WAY-100635 for 5-HT1A and 5-HT7 receptors are 8.8 and 6.5, respectively (32). Drug solutions were administered in a volume of 0.2 ml followed by a 0.2 ml flush of saline.
Statistics and graphical displays. To estimate the differential effects of doses and their standard errors, we fit ordinary least squares regressions with indicator variables for "rat effects" (i.e., interanimal differences in bladder characteristics) and dose effects (25). This is equivalent to a repeated-measures analysis of variance with rats as the blocking variables and the drugs as the treatments. The blocking, which is appropriate because measurements are done within rats, reduces the standard errors relative to incorrectly analyzing the data without adjusting for differences across rats. Such blocking is essential because the variation in outcomes across rats can swamp the variation of outcomes within rats. Regression models were fit separately for each group of rats (intact vs. spinal cord-injured) using all observed data. Hypothesis tests were performed using standard t-tests with Bonferroni corrections for the number of dose levels. All data analysis was performed using S-Plus version 6.0 for Windows (Insightful, Seattle, WA). Diagnostic checks of the model indicate adequate fit.
In each dose-response curve figure, the leftmost value is the average obtained with vehicle treatment for that group. The value at each drug dose equals the vehicle average plus the estimated average effect of the dose relative to vehicle. For example, the vehicle average for micturition volume in spinal cord-injured rats is 0.14 ml [Table 1, and vehicle values (V) in Fig. 3, top, left]. After controlling for differences across rats, the effect of a dose of 0.3 mg/kg 8-OH-DPAT is to add, on average, 0.24 ml to the vehicle average (yielding the starred value of 0.38 ml in Fig. 3, top, left). These estimated dose effects, along with their displayed standard errors, are obtained from the linear regression. The standard errors are appropriate for testing hypotheses that average values at each drug dose differ from average values with vehicle alone. Vehicle averages are not plotted with standard errors because comparisons of vehicle against vehicle are meaningless. However, vehicle averages are given with conventional estimates of mean (SD) in Table 1.
|
|
| RESULTS |
|---|
|
|
|---|
|
|
Dose-response curves for cystometric variables in spinal cord-injured rats are shown in Fig. 3. With increasing doses of 8-OH-DPAT, micturition volume increased from 0.14 ml (SD 0.08) with vehicle to 0.31 ml (SD 0.14) at 1 mg/kg, whereas decreases were seen for residual volume [from 3.68 ml (SD 1.36) to 2.00 ml (SD 0.64)], bladder capacity [from 3.82 ml (SD 1.40) to 2.31 ml (SD 0.67)], and peak intravesical pressure [from 33.2 mmHg (SD 8.3) to 24.8 mmHg (SD 3.0)]. All of these changes were reversed by treatment with the 5-HT1A receptor antagonist WAY-100635 at 0.3 mg/kg iv (Fig. 4). The rise in micturition volume and fall in bladder capacity concomitant with 8-OH-DPAT treatment indicate an improvement in voiding efficiency, taken as the ratio of micturition volume to bladder capacity and expressed as a percentage, from 4.0% (SD 2.7) with vehicle administration to 14.1% (SD 6.7) with 1 mg/kg 8-OH-DPAT, and back to 4.8% (SD 2.7) following 0.3 mg/kg WAY-100635 (Fig. 4). The changes in micturition volume, residual volume, bladder capacity and voiding efficiency all achieved statistical significance between 0.03 and 0.1 mg/kg (Fig. 3). As shown in the Fig. 3, bottom, right, this is also the point at which the number of pauses interpolated into the EUS-EMG rose dramatically from 2.0/micturition (SD 2.8) with vehicle to 18.2/micturition (SD 3.4) at 1 mg/kg. The increase in number of pauses per micturition was also completely reversed with WAY-100635 (Fig. 4).
|
|
|
| DISCUSSION |
|---|
|
|
|---|
|
Increasing afferent drive as the bladder fills also eventually activates a supraspinal "switch" (Fig. 7, top), whereupon descending pathways activate parasympathetic preganglionic neurons of the sacral parasympathetic nucleus (SPN), inducing bladder contraction, and also activate inhibitory interneurons of the dorsal gray commissure (DGC), inhibiting EUS motor neurons and thereby allowing EUS relaxation during bladder contraction. Whereas the EUS is continuously relaxed during voiding in many species including humans, it is phasically relaxed in rats. This requires central pattern generation "in which oscillatory motor output is generated in the absence of any oscillatory input" (11). Whereas central pattern generators typically involve the generation of bursts of activity against a silent background, the central EUS pattern generator may be a "pause generator" that interpolates pauses into the otherwise tonic activity arising from the spinal tonic EUS reflex (14). We have schematized this in Fig. 7, top as being due to DGC inhibitory interneurons, which exhibit self inhibition (31) such that their activation quickly leads to their inhibition, which again permits their excitation, and so on. The self-inhibition may actually depend upon polysynaptic rather than monosynaptic connections; for example, the same effect would be achieved if the DGC interneurons inhibit those neurons responsible for their excitation. This interpretation leads to the recognition that micturition in humans and rats is more similar than is commonly believed; the rat simply has periodic rather than tonic relaxation during voiding.
Complete spinal cord injury generally prevents tonic relaxation of the EUS in humans during voiding contractions (1, 30) and similarly prevents phasic relaxation of the EUS in deeply urethane-anesthetized spinal cord-injured rats. This markedly decreases voiding efficiency, which can be improved in both humans (9, 22) and rats (37) by enforcing EUS relaxation with neuromuscular blockade. The present study shows that 8-OH-DPAT administration restores phasic relaxation of the EUS in urethane-anesthetized chronic spinal cord-injured rats and by this quite different mechanism increases voiding efficiency.
In spinally intact rats, in which phasic EUS relaxation is already effective in appropriately lowering urethral resistance during bladder contractions, 8-OH-DPAT correspondingly had very little effect on cystometric variables. This is not surprising, given that increasing the duration of individual phasic relaxations might either antagonize or promote efficient voiding in spinally intact rats. Thus, in those spinally intact rats that had numerous phasic relaxations before drug treatment, the lengthening of relaxations could actually antagonize efficient voiding, given that complete blockade of EUS contractions in spinally intact rats with
-bungarotoxin reduces voiding efficiency (37). On the other hand, in spinally intact rats with infrequent phasic relaxations before drug treatment, voiding efficiency could presumably be enhanced. These speculations must be conditioned by at least two other crucial considerations: 1) augmented phasic relaxation outliving the length of the bladder contraction, assuming that is possible, cannot improve voiding efficiency; and 2) voiding efficiency cannot be improved beyond 100% (which it regularly approaches or attains in spinally intact rats; see Fig. 6).
In any case, that 8-OH-DPAT modified EUS-EMG pause generation both in some spinally intact rats and in chronic spinal cord-injured rats suggests that the same pattern generator is being targeted in both spinally intact and chronic spinal cord-injured rats and that in both cases the central EUS pattern generator has a spinal locus rather than a supraspinal one. The mechanism underlying the rat's central EUS pattern generator is unknown. However, while 8-OH-DPAT can induce pauses in urethane-anesthetized chronic spinal cord-injured rats, 5-HT input cannot be a requirement for pause generation in conscious rats. First, as shown in this study, WAY-100635 does not affect pause generation in spinally intact rats. Second, pauses resume in conscious rats with chronic complete midthoracic spinal cord transection (4) in which descending 5-HT input has been irreversibly removed (23, 26).
Sustained excitatory input to the DGC inhibitory interneurons during the micturition contraction is a crucial part of the generation of phasic activity. Since this input is lost upon transection, plasticity in the form of replacement of lost supraspinal inputs with new inputs, perhaps from the same afferent neurons driving the spinal tonic EUS reflex, would have to develop. Similar problems beset other hypothetical mechanisms. Thus, even if the elements of the spinal EUS pattern generator remain (explaining the conserved pattern of phasic relaxation in chronic spinal cord-injured rats), spinal cord plasticity must occur for activation of the spinal pattern generator. The locus and even the timing of such plasticity remain unknown, which is schematically represented in Fig. 7, bottom, as being due to spinal micturition reflex neurons, which could be projection neurons, excitatory interneurons innervating Onuf's nucleus, or other interneurons.
It must be noted that activation of bladder contraction, and subsequently of pause generation, may require a switch mechanism just as in spinally intact rats. In spinally intact rats, the switch is located in the pons (Fig. 7, top); excitatory output to the SPN parasympathetic preganglionic neurons (and to the spinal EUS pattern generator) occurs when the switch is closed, leading to the sudden generation of high bladder pressures from a low threshold value. The rapid rise and fall in bladder pressure, which is the ultimate sign of switch activity (just as sudden pontine neuronal output is the proximate sign), also occurs in chronic spinal cord-injured rats whether open or isovolumic cystometry is employed. Certainly, the rapid rise in bladder pressure indicates that SPN parasympathetic preganglionic neuronal output is not the consequence of a gradual monosynaptic increase in afferent input. Conceivably there could be a switch-like increase of afferent input due to the sudden activation of a set of previously silent afferent neurons, which would have to be capsaicin-insensitive fibers, because the spinal micturition reflex in the chronic spinal cord-injured rat survives capsaicin treatment (5). In any case, we suggest that the switch in chronic spinal cord-injured rats has a spinal locus and that its activation by afferent neurons drives the SPN parasympathetic preganglionic neurons.
Our hypothetical framework for coordinated bladder contraction and phasic EUS relaxation in the chronic spinal cord-injured rat thus includes a capsaicin-insensitive afferent input to a switch, which, just as in the intact rat, directly or indirectly controls excitation of the parasympathetic preganglionic neurons. Because phasic EUS relaxation is not seen except in the setting of a bladder contraction, we assume that activation of the switch is required for activation of the spinal EUS pattern generator. Because spinal micturition reflex-driven voiding contractions occur in tandem with phasic relaxation (this study and Ref. 4), the switch must be found proximal to both SPN parasympathetic preganglionic neurons and the spinal EUS pattern generator (Fig. 7, bottom). We have schematized the limb of the reflex pathway, which activates the EUS pattern generator to emphasize three important features. It is inhibited by urethane, because phasic relaxation occurs in chronic spinal cord-injured rats that are conscious (4) but not in those that are urethane-anesthetized (e.g., pre-8-OH-DPAT rats in this study). It is stimulated by 8-OH-DPAT (this study). It is apparently either absent or inhibited in humans, for which reason humans maintain bladder-sphincter dyssynergia. It may additionally be inhibited by
2 opiate receptor agonists as it is in spinally intact rats (14). It remains to be demonstrated when the EUS pattern generator is restored after spinal cord injury, whether it is ever truly lost as opposed to merely being separated from its excitatory input, and finally whether the human analog (which yields tonic rather than phasic relaxation) can be activated in humans after spinal cord injury.
| ACKNOWLEDGMENTS |
|---|
Material in this manuscript was presented, in part, at the 2003 annual meeting of the Society for Neuroscience (10) and the 2004 annual meeting of the American Urological Association (13).
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
| REFERENCES |
|---|
|
|
|---|
1-adrenoceptors and 5-HT1A receptors in the control of the micturition reflex in male anaesthetized rats. Br J Pharmacol 133: 6172, 2001.[CrossRef][Web of Science][Medline]
1- and
2-noradrenergic and serotonin1A receptors in the spinal cord of normal and chronically transected cats. J Comp Neurol 406: 402414, 1999.[CrossRef][Web of Science][Medline]
2 opioid receptor agonists in the female rat. J Urol 171: 472477, 2004.[CrossRef][Web of Science][Medline]
-adrenergic stimulation. J Urol 131: 11221126, 1984.[Web of Science][Medline]
-bungarotoxin, a neuromuscular junction blocking agent, on voiding dysfunction in the rat with spinal cord injury. Urology 55: 956960, 2000.[CrossRef][Web of Science][Medline]This article has been cited by other articles:
![]() |
M. Miyazato, Y. Kaiho, I. Kamo, T. Kitta, M. B. Chancellor, K. Sugaya, Y. Arai, W. C. de Groat, and N. Yoshimura Role of spinal serotonergic pathways in sneeze-induced urethral continence reflex in rats Am J Physiol Renal Physiol, October 1, 2009; 297(4): F1024 - F1031. [Abstract] [Full Text] [PDF] |
||||
![]() |
X. Zhang, K. L. Douglas, H. Jin, B. M. Eldaif, R. Nassar, M. O. Fraser, and P. C. Dolber Sprouting of substance P-expressing primary afferent central terminals and spinal micturition reflex NK1 receptor dependence after spinal cord injury Am J Physiol Regulatory Integrative Comp Physiol, December 1, 2008; 295(6): R2084 - R2096. [Abstract] [Full Text] [PDF] |
||||
![]() |
S.-F. Pan, H.-Y. Peng, C.-C. Chen, M.-J. Chen, S.-D. Lee, C.-L. Cheng, J.-C. Shyu, J.-M. Liao, G.-D. Chen, and T.-B. Lin Nicotine-activated descending facilitation on spinal NMDA-dependent reflex potentiation from pontine tegmentum in rats Am J Physiol Renal Physiol, May 1, 2008; 294(5): F1195 - F1204. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |